ALL-5 Barrel AC

ALL-5 Barrel AC

PRODUCT DESCRIPTION

ALL-5 electrical grease pumps are manufactured for lubrication purpose only. Pump displacement is variable to provide required lubrication needs. Pump system doesn’t have a lubricant reservoir. Standard grease barrels can be used as reservoir. Pump systems plunge lenght can be manufactured for diferent barrel volumes. ALL-5 pumps are manufactured with 3 different sizes of grease piston option. Each piston delivers different amount of grese and pressure value to pump outlet. ALL-5 pumps can be selected from 2 principle options which is working with pressure switch or by-pass sysem.

CAUTION : ALL5 pumps are manufactured for lubrication purpose only, for this reason it is not suitable to operate the pump more than 5 minutes.

Motor type : 380 V AC
Maximum pressure : 200 bar.
Motor protection class : IP 54
Grease class : NLGI 00 (-10°C to 0°C)
NLGI 0 (0°C to 10°C)
NLGI 1 (10°C to 30°C)
Pump displacement : (Ø12 piston) 160 cm³/minute
(Ø16 piston) 280 cm³/minute
(Ø20 piston) 445 cm³/minute
Working temperature :  -25°C to 80°C
Reservoir capacity : No Reservoir.
(Standard grease barrels can be used as a reservoir.)

GENERAL DIMENSIONS

PRODUCT COMPONENTS

Product numberVoltageGrease packingPiston sizeSystem
10 38 20 E1380 V AC16 - 20 liters bucketØ12Standard
10 38 20 E2380 V AC16 - 20 liters bucketØ16Standard
10 38 20 E3380 V AC16 - 20 liters bucketØ20Standard
10 38 20 B1380 V AC16 - 20 liters bucketØ12By-pass
10 38 20 B2380 V AC16 - 20 liters bucketØ16By-pass
10 38 20 B3380 V AC16 - 20 liters bucketØ20By-pass

PRECAUTIONS

» Pumps are made for lubrication purposes only and cannot run continiously over 2 hours. Using continiously at maximum pressure might harm the system.

» Washing with pressurized water is not allowed.

» The grease used in the pump should be same as the grease types specified to the model of pump.

» The grease should be Litium based and with EP additive. Pumps can use NLGI 0, 1 and 2 greases. In cold weather NLGI 0 or 1 and warm weather NLGI 2 should be used.

» The grease used should be absolutely clean and all contamination during bucket change should be avoided.

» Contamination during the filling causes damages to pump, piston and distributors.

» Instructions how to install the pump to a bucket are in operations manual which can be downloaded from SUPPORT menu.

Gallery

Documents

Please click on document below to download instruction and user manual.

ALL-5 Barrel AC ALL-5 AC Manual