LUBMATIC Mini DC Timer

LUBMATIC Mini DC Timer

PRODUCT DESCRIPTION

LUBMATIC Mini Timer series are electric oil pumps manufactured for only lubrication purpose. LUBMATIC series have wide range of application area in machinery and equipments. LUBMATIC pumps are specially designed to use with single line lubrication systems. Pressure relief valve and by-pass system is standard and integrated with pump design. Timer series LUBMATIC pumps have advanced electronic control unit integrated with motor cover. Waiting and working time period programming and also system monitoring can be done by integrated control unit.

Motor type

:

24 V DC

Min. working pressure
Max. working pressure

:

40 bar. / 580 psi
70 bar. / 1015 psi

Liquid grease types

:

NLGI 0000
NLGI 000

Oil types

:

40 (ISO grade)
and up to
220 (ISO grade)

Operating temperature

:

 -25°C, +80°C

Reservoir capacities

:

1,5 Liters

Displacement

:

250 cm³ / minute

Motor protection class

:

IP 54

Control card voltage

:

10 – 30 V DC

Working time period

:

1 sec. to 99 minutes

Waiting time period

:

1 sec. to 99 hours

Warnings

:

Fuse broken, Fault, Alarm

Outlet connection

:

M10x1 – Ø6mm

 Product number 10 24 TM 03 

GENERAL DIMENSIONS

PRODUCT COMPONENTS

ELECTRONIC CONTROL UNIT

WAIT : Yellow LED (Indicates waiting period is on)

LUB. : Green LED (Indicates working period is on)
WARN. : Red LED (Indicates alarm mode is on)
PROGRAM : This screen shows all necessary information about programming.
SERVICE : This button is used to start programing and applying changes.

ADDITIONAL CYCLE : This button operates an additional lubrication cycle any time its pressed.

PROGRAMMING INSTRUCTIONS

1. Press SERVICE Button twice to enter program mode. After entering program mode first digit on program display and green led start to flash. Working time period will be set first.

2. ADDITIONAL CYCLE button changes the numbers shown in flashing digit. Press Additional cycle button until desired number shown in flashing digit. Press SERVICE button to save digit.

3. After first digit saved, second digit starts to flash. ADDITIONAL CYCLE button changes the numbers shown in flashing digit. Press Additional cycle button until desired number shown in flashing digit. Press SERVICE button to save digit. 

4. After second digit saved, time unit leds start to flash. ADDITIONAL CYCLE button changes the time units. Press Additional cycle button until desired time unit is flashing. Press SERVICE button to save time unit.

Working time period is saved and setted. After this section waiting time period wil be set.

5. After seting working time unit, first digit on program display and yellow led start to flash. Waiting time period will be set.

6. ADDITIONAL CYCLE button changes the numbers shown in flashing digit. Press Additional cycle button until desired number shown in flashing digit. Press SERVICE button to save digit.

7. After first digit saved, second digit starts to flash. ADDITIONAL CYCLE button changes the numbers shown in flashing digit. Press Additional cycle button until desired number shown in flashing digit. Press SERVICE button to save digit.

8.  After second digit saved, time unit leds start to flash. ADDITIONAL CYCLE button changes the time units. Press Additional cycle button until desired time unit is flashing. Press SERVICE button to save time unit.

Waiting time period is saved and setted. Programming of the Integrated control card is now complated. Integrated control card starts the pump with working time period.

While integrated control card is on, If ADDITIONAL CYCLE button pressed 2 seconds long remaining time period will be shown on program display.

PRECAUTIONS

1. Damages that occur during additional transportation after the goods are delivered from ALLFETT to the customer VOIDS THE WARRANTY.

2. Pumps are produced for lubrication purpose only and are not meant to work for more than 2 hours continuously. Working under maximum pressure for more than 2 hours will harm the system. Damages occur from this reason VOIDS THE WARRANTY. 

3. Washing of the components with pressured water causes damage. Any damage occur from this reason VOIDS THE WARRANTY.

4. Pump reservoir is made of transparent material to see grease level. Painting any part of the pump is not recomended. Any painted parts VOIDS THE WARANTY.

5. Pumps have an electric driven motor. Electrical lines must be connected properly as described in PAGE 10 - 11 and applied only by qualified and instructed personel. 

6. All electrical connections and lines must be checked regularly for damage and to be ensured that they are firmly in place.

7. Damages coming from voltage fluctuation, wrong electrical installation, connecting wrong voltage to product VOIDS THE WARANTY.

8. Keeping an uncovered cable(s) during system assembly may cause fatal damages where high voltage is transformed to low voltage. Lines must be connected properly to prevent personal injury and damage to property.

9. Transformer is necessary if there is no “ 24 V DC ”  electrical source. Use minimum 5A current transformer. 

10. Only proper ISO class lubricants must be used within system. 

11. Only LITHIUM based and EP additive lubricants must be used within system.

12. Rubber based lubricant types must not be used in the system. Damages or faults occur from this reason VOIDS THE WARANTY.

13. Lubricant that will be used in the system must certainly be clean and any foreign materials must not enter while filling. 

14. Any foreign materials, dirt or small particles while filling lead to system units failing and possibly property damage to equipments. Damages or faults occur from this reason VOIDS THE WARANTY. 

15. Pump must be filled from the filling cover if lubricant level is lower than the minimum level.

16. Environment must be clean to avoid any foreign materials entering to reservoir while filling. Any foreign materials, dirt or small particles while filling will lead to system units failing and possibly property damage. Damages or faults occur from this reason VOIDS THE WARANTY. 

17. If the pump works without lubricant, pump system will send air to the points instead of grease. Because of that any points connected to pump will not get any lubricant. Damages on pump and on the system because that reason VOIDS THE WARANTY.

18. Disassembling or loosing any part while pump working is prohibited. Any damage because of this reason VOIDS THE WARRANTY. Also for any personal injury occurred from this reason ALLFETT does not accept any responsibility.

19. Unauthorised modifications to the units and the use of unauthorised spare parts and aids is prohibited and VOIDS THE WARRANTY. Only maintenance may apply that is described in PAGE 14 - 15. ALLFETT Technical Service must be informed for any other possible troubles and necessary procedures must be performed.

20. ALLFETT Mekanik ve Elektronik Sistemler SAN. TIC. LTD. STI and ALLFETT Pazarlama ve Dis Ticaret LTD. STI. does not accept responsibility for damages described in items above on equipments which ALLFETT systems are installed.

Gallery

Documents

Please click on document below to download instruction and user manual.

LUBMATIC Mini DC Timer LUBMATIC Mini Tm Manual