ALL-1 Pump Element

ALL-1 Pump Element

PRODUCT DESCRIPTION

Pump elements are piston type pressure units for electrical grease pumps. Designed to use with ALL-1, ALL-10 and ALL-25 series ALLFETT electrical grease pumps. Pump elements are installed on to pump body. Each pump has different outlet properties to installing pump elements.

Compatible pump types
: ALL-1, ALL-10, ALL-25 series
Max.pressure : 400 bar.
(Security valve factory adjustment)
Pump element piston sizes
: Ø5mm, Ø6mm ve Ø7mm
Outlet connection
: M10x1 - Ø6mm
Grease types
: NLGI 000 (-40°C to -30°C)
NLGI 00 (-30°C and -10°C)
NLGI 0 (-10°C and 0°C)
NLGI 1 (0°C and 10°C)
NLGI 2 (10°C and 30°C)
NLGI 3 (30°C and up)
Pump element displacement
(Pumps with DC motor)
: Ø5mm - 1,5 cm³ / minute
Ø6mm - 2,5 cm³ / minute
Ø7mm - 3,5 cm³ / minute
Pump element displacement
(Pumps with AC motor)
: Ø5mm - 5 cm³ / minute
Ø6mm - 7,5 cm³ / minute
Ø7mm - 9 cm³ / minute

 

GENERAL DIMENSIONS

PARTS LIST

Product numberDescriptionPistonDiameter Type
10 00 05 02 Pump elementØ5Standard
10 00 06 02 Pump element Ø6Standard
10 00 07 02 Pump elementØ7 Standard
10 00 05 03 Pump elementØ5With pressure switch
10 00 06 03 Pump element Ø6With pressure switch
10 00 07 03 Pump element Ø7With pressure switch
10 01 05 02 Pump element Ø5With grease nipple
10 01 06 02 Pump element Ø6With grease nipple
10 01 07 02 Pump element Ø7With grease nipple

PRECAUTIONS

1. Damages that occur during additional transportation after the goods are delivered from ALLFETT to the customer VOIDS THE WARRANTY.

2. Pumps are produced for lubrication purpose only and are not meant to work for more than 2 hours continuously. Working under maximum pressure for more than 2 hours will harm the system. Damages occur from this reason VOIDS THE WARRANTY. 

3. Washing of the components with pressured water causes damage. Any damage occur from this reason VOIDS THE WARRANTY. 

4. Pump reservoir is made out of transparent material to see the grease level. Painting any part of the pump is not recommended. Any painted parts VOID THE WARRANTY.

5. Pumps have an electrically driven motor. Electrical lines must be connected properly as described in PAGE 10 - 11 and should be applied only by qualified and instructed personnel. 

6. All electrical connections and lines must be checked regularly for damage to ensure that they are firmly in place.

7. Damages occurring from voltage fluctuation, wrong electrical installation, connection to wrong voltage VOIDS THE WARANTY.

8. Keeping an uncovered cable(s) during system assembly may cause fatal damages where high voltage is transformed to low voltage. Lines must be connected properly to prevent personal injury and damage to property.

9. A transformer is necessary if there is no “ 24 V DC ”  electrical source. Use minimum 5A current transformer. 

10. Only proper NLGI class lubricants must be used within system. NLGI class must be changed according to weather conditions. Use NLGI 0 for cold weather, increase the NLGI class up to 3 towards hot weathers.

11. Only LITHIUM based and EP additive lubricants must be used with in system.

12. Rubber based lubricant types must not be used in the system. Damages or faults occur from this reason VOIDS THE WARRANTY.

13. Lubricant to be used in the system must certainly be clean and any foreign materials must not enter while filling. 

14. Any foreign materials, dirt or small particles while filling may lead to system units failing and possibly property damage to equipments. Damages or faults occurring from this reason VOIDS THE WARRANTY. 

15. Pump must be filled from the grease nipple. If grease level is lower than the minimum level (when you can not see the grease level) grease nipple must be used to prevent air entering inside the pomp body. Locking filling cover option can only be used after filling pump from grease nipple up to minimum level.

16. If locking filling cover is going to be used to fill pump, environment must be clean to avoid any foreign materials from entering to reservoir. Any foreign materials, dirt or small particles while filling lead to system units failing and possibly property damage. Damages or faults occur from this reason VOIDS THE WARRANTY. 

17. If the pump works without lubricant, pump elements will send air to the points instead of grease. Because of that any points connected to pump will not get any lubricant. Damages on pump and on the system because that reason VOIDS THE WARRANTY.

18. Disassembling or loosing any part while pump working is prohibited. Any damage because of this reason VOIDS THE WARRANTY. Also for any personal injury occurred from this reason ALLFETT does not accept any responsibility.

19. Another goal of Centralized Lubrication Systems is to protect environment. So it is advised to fill grease to the systems with mobile or hand pumps. 

20. Unauthorised modifications to the units and the use of unauthorised spare parts and aids is prohibited and VOIDS THE WARRANTY. Only maintenance may apply that is described in PAGE 14 - 15. ALLFETT Technical Service must be informed for any other possible troubles and necessary procedures must be performed.

21. ALLFETT Mekanik ve Elektronik Sistemler SAN. TIC. LTD. STI and ALLFETT Pazarlama ve Dis Ticaret LTD. STI. does not accept responsibility for damages described in items above on equipments which ALLFETT systems are installed.