ALL-6 Cartridge pump

ALL-6 Cartridge pump

PRODUCT DESCRIPTION

ALL- 6 series are piston type electrical grease pumps designed to be used with small machinery and equipments. Replaceble grease cartridge is used as a reservoir. 350 gram and 675 gram capacity cartridges eliminates any kind of problem related on filling and also makes this process easier. 

Electrical connections of the pump can easily be done by electrical socket placed onto motor cover. DC type motor voltages can be selected from 12 or 24 Volts. This pump can also be used with ALLFETT electronic control cards if necessary.

In case the pump is installed so that operator cannot see the level of grease, the ALLFETT low level sensor can be used to follow the level of grease in cartridges.

Motor type

:

12 - 24 V DC

Max. pressure

:

150 bar.

Motor protection class

:

IP 54

Grease Type

:

NLGI 00 (-30°C with -10°C)
NLGI 0 (-10°C with 0°C)
NLGI 1 (0°C with 10°C)
NLGI 2 (10°C with 30°C)
NLGI 3 (30°C ve over)

Pump element displacement

:

4,5 cm³ / minute

Operating temperature

:

 -40°C, +80°C

Cartridge capacity

:

350 gram

Outlet connection

:

M10x1 – Ø6mm


GENERAL DIMENSIONS


PARTS LIST

Product number

Product Name

Voltage

Reservoir capacity

Outlets

10 12 06 A5

ALL-6 Pump

12 V DC

350 gram

1

10 24 06 A5

ALL-6 Pump

24 V DC

350 gram

1




Product number

Product Name

Capacity

Content

GR 00 02 BE

Grease cartridge

350 gram

Empty

GR 35 00 02

Grease cartridge

350 gram

NLGI 2 Grease


PRECAUTIONS

1. Damages occur while additional transports after delivering the goods from ALLFETT to the customer DISQUALIFIES THE WARANTY.

2. 
Pumps are produced to lubrication purpose only and are not convenient to work more than 2 hours continuously. Working under maximum pressure more than 2 hours will harm the system. Damages occur from this reason DISQUALIFIES THE WARANTY.

3. Washing of the pump with pressured water causes damage. Any damage occur from this reason DISQUALIFIES THE WARANTY.

4. 
Pump reservoir is made of semi-transparent material to see grease level. Painting any part of the pump is not recomended. Any painted parts DISQUALIFY THE WARANTY.

5. 
Pumps have an electric driven motor. Electrical lines must be connected properly as described in user manual and applied only by qualified and instructed personel.

6. 
All electrical connections and lines must be checked regularly for damage and to ensure that they are firmly in place.

7. 
Damages coming from voltage fluctuation, wrong electricity installation, connecting wrong voltage to product DISQUALIFIES THE WARANTY.

8. 
Keeping an uncovered cable(s) during system assembly may cause fatal damages where high voltage is transformed to low voltage. Lines must be connected properly to prevent personal injury and damage to property.

9. Transformer is necessary if there is no “ 24 V DC ”  electrical source. Use minimum 5A current transformer.

10. 
Only proper NLGI class lubricants must be used with in system. NLGI class must be changed according to weather conditions. Use NLGI 0 for cold weather, increase the NLGI class up to 3 towards hot weathers.

11. Only LITHIUM based and EP additive lubricants must be used with in system.

12. 
Rubber based lubricant types must not be used in the system. Damages or faults occur from this reason DISQUALIFIES THE WARANTY.

13. 
Lubricant will be used in the system must certainly be clean and any foreign materials must not enter while changing cartridge.

14. 
Plastic follower piston of cartridge must not be removed due to filling purpose. Grease cartridge must not be filled by removing follower piston.

15. 
Any foreign materials, dirt or small particules while changing grease cartridge lead to system units failing and possibly property damage to equipments. Damages or faults occur from this reason DISQUALIFIES THE WARANTY.

16. 
If the pump works without lubricant, pump elements will send air to the points instead of grease. Because of that any points connected to pump will not get any lubricant. Damages on pump and on the system coming from that reason DISQUALIFIES THE WARANTY.

17. 
Disassembling or loosing any part while pump working is prohibited. Any damage coming from this reason DISQUALIFIES THE WARANTY. Also any personal injury occur from this reason ALLFETT does not accept responsibility.

18. 
Another goal of Centralized Lubrication Systems is to protect environment. So it is adviced to fill  grease to the systems by mobile or hand pumps.

19. 
Unouthorized modifications to the units and the use of unouthorized spare parts and aids prohobited and DISQUALIFIES THE WARANTY. Only maintenance may apply descibed in PAGE 14 - 15. ALLFETT Technical Service must be informed to any other  possible troubles and necessary procedures must be performed.

20. 
ALLFETT Mekanik ve Elektronik Sistemler SAN. TIC. LTD. STI and ALLFETT Pazarlama ve Dis Ticaret LTD. STI. does not accept responsibility for damages described in items above on equipments which ALLFETT systems are installed.

Gallery

Documents

Please click on document below to download instruction and user manual.

ALL-6 Cartridge pump ALL-6 Pump Instruction And User Manual