ALL-10 series

ALL-10 series

PRODUCT DESCRIPTION

ALL-10 electrical grease pumps are manufactured only for lubrication purpose. Pump displacement is various to provide required lubrication needs. Optionally obtained pump element(s) create pressurized grease with different displacement volumes. 1 to 8 pump elements can be added on pump body.

The pump reservoir is manufactured from transparent polycarbonate to allow user to easily check the level of grease. In case of the pump installed in a way that the operator cannot see the level of grease an ALLFETT low level sensor can be used to control the level of grease.

Top filling application is possible with different filling covers, with or without locking. ALL-10 pumps can be controlled and monitored with external electronic control cards. Optional control card feature also displays warnings as broken fuse, fault and alarms.

Motor type

:

220 - 380 V AC

Max. pressure

:

400 bar.

Motor protection class

:

IP 54

Grease Type

:

NLGI 00 (-30°C with -10°C)
NLGI 0 (-10°C with 0°C)
NLGI 1 (0°C with 10°C)
NLGI 2 (10°C with 30°C)
NLGI 3 (30°C ve over)

Pump element displacement

:

5 cm³ / minute
7,5 cm³ / minute
9,5 cm³ / minute

Operating temperature

:

 -25°C to 80°C

Reservoir capacity

:

1,5 - 3,3 - 4 - 6 - 8 - 10 - 12 Liters

Number of pump outlets

:

1 - 8



GENERAL DIMENSIONS

PARTS LIST

ALL-10 PUMPS WITH 1,5 and 3,3 LITER RESERVOIRS





ALL-10 PUMPS WITH 4, 6, 8, 10 and 12 LITER RESERVOIRS

Product number Voltage Reservoir capacity Outlets
10 22 15 A1 220 V AC 1,5 liters  1 - 8
10 22 33 A1 220 V AC 3,3 liters  1 - 8
10 22 04 A1 220 V AC 4 liters  1 - 8
10 22 06 A1 220 V AC 6 liters  1 - 8
10 22 08 A1 220 V AC 8 liters  1 - 8
10 22 10 A1 220 V AC 10 liters  1 - 8
10 22 12 A1 220 V AC 12 liters  1 - 8
10 38 15 A1 380 V AC 1,5 liters  1 - 8
10 38 33 A1 380 V AC 3,3 liters  1 - 8
10 38 04 A1 380 V AC 4 liters  1 - 8
10 38 06 A1 380 V AC 6 liters  1 - 8
10 38 08 A1 380 V AC 8 liters  1 - 8
10 38 10 A1 380 V AC 10 liters  1 - 8
10 38 12 A1 380 V AC 12 liters  1 - 8

PRECAUTIONS

1. Damages that occur during additional transportation after the goods are delivered from ALLFETT to the customer VOIDS THE WARRANTY.

2. Pumps are produced for lubrication purpose only and are not meant to work for more than 2 hours continuously. Working under maximum pressure for more than 2 hours will harm the system. Damages occur from this reason VOIDS THE WARRANTY. 

3. Washing of the components with pressured water causes damage. Any damage occur from this reason VOIDS THE WARRANTY. 

4. Pump reservoir is made out of transparent material to see the grease level. Painting any part of the pump is not recommended. Any painted parts VOID THE WARRANTY.

5. Pumps have an electrically driven motor. Electrical lines must be connected properly as described in PAGE 10 - 11 and should be applied only by qualified and instructed personnel. 

6. All electrical connections and lines must be checked regularly for damage to ensure that they are firmly in place.

7. Damages occurring from voltage fluctuation, wrong electrical installation, connection to wrong voltage VOIDS THE WARANTY.

8. Keeping an uncovered cable(s) during system assembly may cause fatal damages where high voltage is transformed to low voltage. Lines must be connected properly to prevent personal injury and damage to property.

9. A transformer is necessary if there is no “ 24 V DC ”  electrical source. Use minimum 5A current transformer. 

10. Only proper NLGI class lubricants must be used within system. NLGI class must be changed according to weather conditions. Use NLGI 0 for cold weather, increase the NLGI class up to 3 towards hot weathers.

11. Only LITHIUM based and EP additive lubricants must be used with in system.

12. Rubber based lubricant types must not be used in the system. Damages or faults occur from this reason VOIDS THE WARRANTY.

13. Lubricant to be used in the system must certainly be clean and any foreign materials must not enter while filling. 

14. Any foreign materials, dirt or small particles while filling may lead to system units failing and possibly property damage to equipments. Damages or faults occurring from this reason VOIDS THE WARRANTY. 

15. Pump must be filled from the grease nipple. If grease level is lower than the minimum level (when you can not see the grease level) grease nipple must be used to prevent air entering inside the pomp body. Locking filling cover option can only be used after filling pump from grease nipple up to minimum level.

16. If locking filling cover is going to be used to fill pump, environment must be clean to avoid any foreign materials from entering to reservoir. Any foreign materials, dirt or small particles while filling lead to system units failing and possibly property damage. Damages or faults occur from this reason VOIDS THE WARRANTY. 

17. If the pump works without lubricant, pump elements will send air to the points instead of grease. Because of that any points connected to pump will not get any lubricant. Damages on pump and on the system because that reason VOIDS THE WARRANTY.

18. Disassembling or loosing any part while pump working is prohibited. Any damage because of this reason VOIDS THE WARRANTY. Also for any personal injury occurred from this reason ALLFETT does not accept any responsibility.

19. Another goal of Centralized Lubrication Systems is to protect environment. So it is advised to fill grease to the systems with mobile or hand pumps. 

20. Unauthorised modifications to the units and the use of unauthorised spare parts and aids is prohibited and VOIDS THE WARRANTY. Only maintenance may apply that is described in PAGE 14 - 15. ALLFETT Technical Service must be informed for any other possible troubles and necessary procedures must be performed.

21. ALLFETT Mekanik ve Elektronik Sistemler SAN. TIC. LTD. STI and ALLFETT Pazarlama ve Dis Ticaret LTD. STI. does not accept responsibility for damages described in items above on equipments which ALLFETT systems are installed.

Gallery

Documents

Please click on document below to download instruction and user manual.

ALL-10 series ALL-10 User Manual