ALL-1 series
PRODUCT DESCRIPTION
ALL-1 electrical grease pumps are manufactured only for lubrication purpose. Pump displacement is varius to provide required lubrication needs. Optionally obtained pump element(s) creates pressurized grease out with different displacement volumes. 1 and up to 6 pump elements can be added on pump body.
The pump reservoir is manufactured from transparent polycarbonate to allow user easily check the level of grease. In case the pump is installed so that operator cannot see the level of grease the ALLFETT low level sensor can be used to follow the level of grease. Top filling application is possible with different filling covers, with or without lock.
ALL-1 pumps can be controlled and monitored with integrated electronic control cards. Optional control card feature also displays warnings as broken fuse, fault and alarms.
Motor type |
: |
12 - 24 V DC |
Max. pressure |
: |
400 bar. |
Motor protection class |
: |
IP 54 |
Control card protection class |
: |
IP 65 |
Grease Type |
: |
NLGI 000 (-40°C with
-30°C) |
Pump element displacement |
: |
1,5 cm³ / minute |
Operating temperature |
: |
-40°C, +80°C |
Reservoir capacity |
: |
1,5 - 3,3 - 4 - 6 - 8 - 10 - 12 Liters |
Control card voltage |
: |
10 - 30 V DC |
Adjustable working period |
: |
1 sec. to 99 minutes |
Adjustable waiting period |
: |
1 sec to 99 hours |
Warnings |
: |
Fuse broken, Fault, Alarm |
Number of pump outlets |
: |
1 - 6 |
GENERAL DIMENSIONS
PARTS LIST
INTEGRATED CONTROL CARD (OPTIONAL)
ALL-1 pumps can be controlled with electronic control card placed onto motor cover. With the optional control unit working and waiting time periods can be controlled and the warnings can be displayed. Electronic control cards are built with high quality components which accomodates military standards. With the control card cover which has IP 65 protection classification, control card can be operated in tough outdoor applications
Please click here for more detailed information about integrated control card.
Product number | Voltage | Reservoir capacity | Outlets |
10 12 15 A1 | 12 V DC | 1,5 liters | 1 - 6 |
10 12 33 A1 | 12 V DC | 3,3 liters | 1 - 6 |
10 12 04 A1 | 12 V DC | 4 liters | 1 - 6 |
10 12 06 A1 | 12 V DC | 6 liters | 1 - 6 |
10 12 08 A1 | 12 V DC | 8 liters | 1 - 6 |
10 12 10 A1 | 12 V DC | 10 liters | 1 - 6 |
10 12 12 A11 | 12 V DC | 12 liters | 1 - 6 |
10 24 15 A1 | 24 V DC | 1,5 liters | 1 - 6 |
10 24 33 A1 | 24 V DC | 3,3 liters | 1 - 6 |
10 24 04 A1 | 24 V DC | 4 liters | 1 - 6 |
10 24 06 A1 | 24 V DC | 6 liters | 1 - 6 |
10 24 08 A1 | 24 V DC | 8 liters | 1 - 6 |
10 24 10 A1 | 24 V DC | 10 liters | 1 - 6 |
10 24 24 A1 | 24 V DC | 12 liters | 1 - 6 |
PRECAUTIONS
1. Damages that occur during additional transportation after the goods are delivered from ALLFETT to the customer VOIDS THE WARRANTY.
2. Pumps are produced for lubrication purpose only and are not meant to work for more than 2 hours continuously. Working under maximum pressure for more than 2 hours will harm the system. Damages occur from this reason VOIDS THE WARRANTY.
3. Washing of the components with pressured water causes damage. Any damage occur from this reason VOIDS THE WARRANTY.
4. Pump reservoir is made out of transparent material to see the grease level. Painting any part of the pump is not recommended. Any painted parts VOID THE WARRANTY.
5. Pumps have an electrically driven motor. Electrical lines must be connected properly as described in PAGE 10 - 11 and should be applied only by qualified and instructed personnel.
6. All electrical connections and lines must be checked regularly for damage to ensure that they are firmly in place.
7. Damages occurring from voltage fluctuation, wrong electrical installation, connection to wrong voltage VOIDS THE WARANTY.
8. Keeping an uncovered cable(s) during system assembly may cause fatal damages where high voltage is transformed to low voltage. Lines must be connected properly to prevent personal injury and damage to property.
9. A transformer is necessary if there is no “ 24 V DC ” electrical source. Use minimum 5A current transformer.
10. Only proper NLGI class lubricants must be used within system. NLGI class must be changed according to weather conditions. Use NLGI 0 for cold weather, increase the NLGI class up to 3 towards hot weathers.
11. Only LITHIUM based and EP additive lubricants must be used with in system.
12. Rubber based lubricant types must not be used in the system. Damages or faults occur from this reason VOIDS THE WARRANTY.
13. Lubricant to be used in the system must certainly be clean and any foreign materials must not enter while filling.
14. Any foreign materials, dirt or small particles while filling may lead to system units failing and possibly property damage to equipments. Damages or faults occurring from this reason VOIDS THE WARRANTY.
15. Pump must be filled from the grease nipple. If grease level is lower than the minimum level (when you can not see the grease level) grease nipple must be used to prevent air entering inside the pomp body. Locking filling cover option can only be used after filling pump from grease nipple up to minimum level.
16. If locking filling cover is going to be used to fill pump, environment must be clean to avoid any foreign materials from entering to reservoir. Any foreign materials, dirt or small particles while filling lead to system units failing and possibly property damage. Damages or faults occur from this reason VOIDS THE WARRANTY.
17. If the pump works without lubricant, pump elements will send air to the points instead of grease. Because of that any points connected to pump will not get any lubricant. Damages on pump and on the system because that reason VOIDS THE WARRANTY.
18. Disassembling or loosing any part while pump working is prohibited. Any damage because of this reason VOIDS THE WARRANTY. Also for any personal injury occurred from this reason ALLFETT does not accept any responsibility.
19. Another goal of Centralized Lubrication Systems is to protect environment. So it is advised to fill grease to the systems with mobile or hand pumps.
20. Unauthorised modifications to the units and the use of unauthorised spare parts and aids is prohibited and VOIDS THE WARRANTY. Only maintenance may apply that is described in PAGE 14 - 15. ALLFETT Technical Service must be informed for any other possible troubles and necessary procedures must be performed.
21. ALLFETT Mekanik ve Elektronik Sistemler SAN. TIC. LTD. STI and ALLFETT Pazarlama ve Dis Ticaret LTD. STI. does not accept responsibility for damages described in items above on equipments which ALLFETT systems are installed.